english
compliance with standards:
qb / t2411-1998 and other standards.
technical parameters:
volume (l) | inner bin size h×w×d(cm) | outer bin size h×w×d(cm) |
150 | 50×50×60 | approx. 100x 110 x 150 |
1. temperature range: - 40 ℃ ~ 150 ℃ (optional: - 20 ℃ ~ 150 ℃; 0 ℃ ~ 150 ℃);
2. humidity range: 20 ~ 98% rh;
3. fluctuation / uniformity: ≤± 0.5 ℃ / ± 2 ℃, ± 2.5% rh / 2 ~ 3% rh;
4. quantity of moisture permeable cups: 6;
5. glass dryer: 1 piece:
6. heating time: - 20 ℃ ~ 100 ℃ about 35min;
7. cooling time: about 35min at 20 ℃ ~ - 20 ℃;
8. control system: lcd display touch temperature and humidity controller, single point and programmable control;
9. resolution: 0.1 ℃ / 0.1% rh;
10. sensor: dry and wet bulb platinum resistance pt100;
11. heating system: ni cr alloy electric heater;
12. refrigeration system: imported french "taikang" brand compressor, air-cooled condenser, oil separator, solenoid valve, drying filter, etc;
13. circulation system: adopt extended shaft motor, equipped with high and low temperature resistant stainless steel multi wing wind wheel;
14. material of outer box: sus 304 fog surface line treated stainless steel plate;
15. material of inner box: sus mirror stainless steel plate;
16. insulation layer: polyurethane rigid foam glass fiber cotton;
17. door frame material: double layer high and low temperature resistant silicone rubber sealing strip;
18. standard configuration: 1 set of multi-layer heating defrosting with lighting glass window and 2 test object racks;
19. 1 test lead hole (50mm);
20. safety protection: overtemperature, motor overheating, compressor overpressure, overload and overcurrent protection;
21. heating, humidification, air incineration, under phase and reverse phase;
22. power supply voltage: ac380v ± 10% 50 ± 1hz three-phase four wire system;
23. operating ambient temperature: 5 ℃ ~ 30 ℃ ≤ 85% rh;